[1]金君,王树雄,于浩,等.氢氧化镍/过氧化聚吡咯修饰电极的制备及电催化氧化[J].江西师范大学学报(自然科学版),2014,(01):1-5.
 JIN Jun,WANG Shu-xiong,YU Hao,et al.The Preparation of Ni(OH) 2/PPyox/CCE Chemical Modified Electrode and the Electrocatalysis for Glucose[J].Journal of Jiangxi Normal University:Natural Science Edition,2014,(01):1-5.
点击复制

氢氧化镍/过氧化聚吡咯修饰电极的制备及电催化氧化()
分享到:

《江西师范大学学报》(自然科学版)[ISSN:1006-6977/CN:61-1281/TN]

卷:
期数:
2014年01期
页码:
1-5
栏目:
出版日期:
2014-02-28

文章信息/Info

Title:
The Preparation of Ni(OH) 2/PPyox/CCE Chemical Modified Electrode and the Electrocatalysis for Glucose
作者:
金君;王树雄;于浩;简选;郑笑晨;刘冉彤;齐广才
延安大学化学与化工学院,陕西延安,716000;陕西延长石油(集团)有限责任公司管道运输公司,陕西延安,716000
Author(s):
JIN Jun;WANG Shu-xiong;YU Hao;JIAN Xuan;ZHENG Xiao-chen;LIU Ran-tong;QI Guang-cai
关键词:
氢氧化镍过氧化聚吡咯葡萄糖
Keywords:
nickel hydroxideperoxide polypyrroleglucose
分类号:
O657.1
文献标志码:
A
摘要:
采用电化学方法制备了纳米氢氧化镍/过氧化聚吡咯复合膜修饰电极(Nano-Ni(OH)2/PPyox),研究了该修饰电极的电化学性质及其电催化活性.结果表明:在0.10 mol·L-1 NaOH溶液中,该修饰电极对葡萄糖具有较强的电催化活性,且具有良好的抗干扰性.在优化实验条件下,安培法检测葡萄糖的线性范围为2.0×10-7 ~5.0×10-5 mol·L-1(r =0.999 7)和5.0×10-5~1.0×10-3 mol·L-1(r=0.999 4),灵敏度分别为1017 μA·mM-1 ·cm-2和733 μA·mM-1·cm-2.
Abstract:
A Ni(OH)2/peroxide polypyrrole composite film modified ceramic carbon electrode(Ni(OH)2/PPyox/CCE)was fabricated by using electrochemical deposition technique.The electrochemical behavior and electrocatalytic activity for the oxidation of glucose were investigated by cyclic voltammetric and amperometric techniques in 0.10 mol·L NaOH solution.The results showed that the resulting modified electrode had high electrocatalytic activity for the oxidation of glucose and anti-interference performance to Vc.Under the optimum conditions,the calibration curve was over the range of 4.98×10 to 4.23×10mol·L(r=0.999 7)and 4.23×10 to 1.67×10 mol·L(r=0.999 4)respectively,with sensitivities of 1 454 μA·mMcmand 1 190 μA·mMcm.

参考文献/References:

[1] Fang A P,Ng H T,Li S F Y.A high-performance glucose biosensor based on monomolecular layer of glucose oxidase covalently immobilised on indium-tin oxide surface [J].Biosens Bioelectron,2003,19(1):43-49.
[2] Clark L C J,Lyons C.Electrode systems for continuous monitoring in cardiovascular surgery [J].Ann NY Acad Sci,1962,102:29-45.
[3] Jia J B,Wang B Q,Wu A G,et al.A method to construct a third-generation horseradish peroxidase biosensor:self-assembling gold nanoparticles to three-dimensional sol-gel network [J].Anal Chem,2002,74(9):2217-2223.
[4] Heller A,Feldman B.Electrochemical glucose sensors and their applications in diabetes management [J].Chem Rev,2008,108(7):2482-2505.
[5] Cao X,Wang N.A novel non-enzymatic electrochemical glucose sensor modified with FeOOH nanowire [J].Electrochem Commun,2010,12(11):1581-1584.
[6] Ma Y T,Di J W,Yan X,et al.Direct electrodeposition of gold nanoparticles on indium tinoxide surface and its application [J].Biosens Bioelectron,2009,24(5):1480-1483.
[7] 方文彦,王凤武,徐迈,等.Ti/nanoTiO2-ZrO2修饰电极电催化氧化葡萄糖 [J].化工学报,2011,61(S1):29-32.
[8] Zhuang Z J,Su X D,Yuan H Y,et al.An improved sensitivity non-enzymatic glucose sensor based on CuO nanowire modified Cu electrode [J].Analyst,2008,133:126-132.
[9] Liu Y,Teng H,Hou H Q,et al.Nonenzymatic glucose sensor based on renewable electrospun Ni nanoparticle-loaded carbon nanofiber paste electrode [J].Biosens Bioelectron,2009,24(11):3329-3334.
[10] Yu X J,Zhuang L N,Yang S C,et al.Sintering improved porous palladium nanoparticle membrane self-assembled at water/pentanol interface for nonenzymatic glucose sensor [J].Colloids Surf:A,2010,372:22-27.
[11] 陈翠莲,魏小兰,沈培康.葡萄糖在纳米Pt/C电极上的电催化氧化 [J].电化学,2006,12(1):20-24.
[12] Qiu H J,Huang X R.Effects of Pt decoration on the electrocatalytic activity of nanoporous gold electrode toward glucose and its potential application for constructing a nonenzymatic glucose sensor [J].Electroanal Chem,2010,643:39-45.
[13] Masato T,Toshihiro S,Makoto N.Electrocatalytic oxidation of glucose at gold-silver alloy,silver and gold nanoparticles in an alkaline solution [J].Electroanal Chem,2006,590(1):37-46.
[14] Mu Y,Jia D L,He Y Y,et al.Nano nickel oxide modified non-enzymatic glucose sensors with enhanced sensitivity through an electrochemical process strategy at high potential [J].Biosens Bioelectron,2001,26:2948-2952.
[15] Wang X Y,Zhang Y,Banks C E,et al.Non-enzymatic amperometric glucose biosensor based on nickel hexacyanoferrate nanoparticle film modified electrodes [J].Colloids Surf:B,2010,78:363-366.
[16] 简选,于浩,金君,等.聚L-组氨酸/石墨烯复合膜修饰电极对多巴胺和尿酸的同时测定 [J].江西师范大学学报:自然科学版,2013,37(3):32-37.
[17] Pihel K,Walker Q D,Wightman R M.Overoxidized polypyrrole-coated fiber microelectrodes for dopamine measurements with fast-scan cyclic voltammetry [J].Anal Chem,1996,68(13):2084-2089.
[18] 金君,于浩,王飞,等.氢氧化铜/过氧化聚吡咯修饰电极的应用 [J].延安大学学报:自然科学版,2011,30(4):39-42.
[19] Tsionsky M,Gun G,Glezer V,et al.Sol-Gel derived ceramic carbon composite electrodes:introduction and scope of application [J].Anal Chem,1994,66(10):1747-1753.

备注/Memo

备注/Memo:
陕西省自然科学基金(2010JQ2005)
更新日期/Last Update: 1900-01-01