[1]宋 玮,钱群丽,卢阳阳,等.基于荧光纳米传感的DEHP快速检测方法研究[J].江西师范大学学报(自然科学版),2021,(04):432-437.[doi:10.16357/j.cnki.issn1000-5862.2021.04.18]
 SONG Wei,QIAN Qunli,LU Yangyang,et al.The Fluorescent Nanosensor-Based Rapid Detection Assay for DEHP[J].Journal of Jiangxi Normal University:Natural Science Edition,2021,(04):432-437.[doi:10.16357/j.cnki.issn1000-5862.2021.04.18]
点击复制

基于荧光纳米传感的DEHP快速检测方法研究()
分享到:

《江西师范大学学报》(自然科学版)[ISSN:1006-6977/CN:61-1281/TN]

卷:
期数:
2021年04期
页码:
432-437
栏目:
化学
出版日期:
2021-08-10

文章信息/Info

Title:
The Fluorescent Nanosensor-Based Rapid Detection Assay for DEHP
文章编号:
1000-5862(2021)04-0432-06
作者:
宋 玮钱群丽卢阳阳宋卫国*
上海市农业科学院,上海 201403
Author(s):
SONG WeiQIAN QunliLU YangyangSONG Weiguo*
Shanghai Academy of Agricultural Sciences,Shanghai 201403,China
关键词:
邻苯二甲酸二(2-乙基)己酯 快速检测 荧光纳米传感器
Keywords:
DEHP rapid detection assay fluorescent nanosensor
分类号:
O 657
DOI:
10.16357/j.cnki.issn1000-5862.2021.04.18
文献标志码:
A
摘要:
采用一锅法制备了超支化聚乙烯亚胺-铜纳米簇(hPEI-Cu NCs),并利用其构建“turn on”荧光纳米传感器对邻苯二甲酸二(2-乙基)己酯(DEHP)进行定量快速检测.hPEI-Cu NCs的最佳激发波长为385 nm,在510 nm处有强发射,透射电镜(TEM)分析结果表明:其形态呈现良好的分散性,粒径为(1.3±0.3)nm.在加入Cu2+后,hPEI-Cu NCs的荧光被Cu2+淬灭; 但当存在DEHP时,Cu2+不能淬灭hPEI-Cu NCs的荧光,且使其荧光强度比不加DEHP时有所上升.随着DEHP质量浓度的增加,hPEI-Cu NCs的荧光逐渐增强,从而达到检测DEHP的目的.荧光强度变化率((I-I0)/I0)与DEHP的质量分数在1.0~7.0 mg·kg-1的范围内呈现良好的线性关系,当信噪比为3 时计算出DEHP的最低检出限约为0.4 mg·kg-1.
Abstract:
A "turn on" fluorescent nanosensor is constructed for rapid detection of DEHP by using one-pot method prepared hPEI-Cu NCs.The best excitation wavelength of hPEI-Cu NCs is 385 nm,and has a strong emission at 510 nm.The morphology of hPEI-Cu NCs is characterized by transmission electron microscopy(TEM).It shows good dispersion and its particle size is(1.3±0.3)nm.After adding Cu2+,the fluorescence of hPEI-Cu NCs is quenched by Cu2+.When DEHP is present,the fluorescence will rise becasuse the fluorescence of hPEI-Cu NCs can not be quenched by Cu2+.With the increase of DEHP concentration,the fluorescence of hPEI-Cu NCs gradually increased,so as to achieve the purpose of detecting DEHP.The fluorescence intensity change rate and DEHP concentration show a good linear relationship in the range of 1.0—7.0 mg·kg-1.When the signaql-to-noise ratio is 3,the lowest detection limit is calculated to be about 0.4 mg·kg-1.

参考文献/References:

[1] Autian J.Toxicity and health threats of phthalate esters:review of the literature [J].Environmental Health Perspectives,1973,4:3-26.
[2] Staples C A,Peterson D R,Parkerton T F,et al.The environmental fate of phthalate esters:a literature review [J].Chemosphere,1997,35(4):667-749.
[3] Xu Gang,Li Fasheng,Wang Qunhui,et al.Occurrence and degradation characteristics of dibutyl phthalate(DBP)and di-(2-ethylhexyl)phthalate(DEHP)in typical agricultural soils of China [J].Science of the Total Environment,2008,393:333-340.
[4] Sun Ruiyan,Zhuang Huisheng.A sensitive heterogeneous biotin-streptavidin enzyme-linked immunosorbent assay for the determination of di-(2-ethylhexyl)phthalate(DEHP)in beverages using a specific polyclonal antibody [J].Analytical Methods,2014,6:9807-9815.
[5] Melnick R L.Is peroxisome proliferation an obligatory precursor step in the carcinogenicity of di-(2-ethylhexyl)phthalate(DEHP)? [J].Environmental Health Perspectives,2001,109:437-442.
[6] Saillenfait A M,Langonne I,Leheup B.Effects of mono-n-butyl phthalate on the development of ratembryos:in vivo and in vitro observations [J].Toxicology and Applied Pharmacology,2001,89(2):104-112.
[7] Aignasse M F,Prognon P,Stachowicz M,et al.A new simple and rapid HPLC method for determination of DEHP in PVC packaging and releasing studies [J].International Journal of Pharmaceutics,1995,113(2):241-246.
[8] Lin Deng,Wu Feng,Deng Nansheng,et al.Determination of trace DEHP in aqueous solution by solid phase microextraction coupled with high performance liquid chromatography [J].Fresenius Environmental Bulletin,2005,14(6):494-497.
[9] Li Boping,Lin Qinbao,Song Huan,et al.Determination of DEHP and DNOP in PVC film by ASE-RP-HPLC [J].Chinese Journal of Applied Chemistry,2008,25(1):63-66.
[10] Pinguet J,Kerckhove N,Eljezi T,et al.New SPE-LC-MS/MS method for the simultaneous determination in urine of 22 metabolites of DEHP and alternative plasticizers from PVC medical devices [J].Talanta,2019,198:377-389.
[11] Cai Zhiming,Zhang Qianlong,Zhao Wenhong,et al.GC-MS determination of phthalates(DBP and DEHP)dissolved from plastic bags [J].Physical Testing and Chemical Analysis,Part B:Chemical,2003,39:529-530.
[12] Sahub C,Tuntulani T,Nhujak T,et al.Effective biosensor based on graphene quantum dots via enzymatic reaction for directly photoluminescence detection of organophosphate pesticide [J].Sensors and Actuators B:Chemical,2018,258:88-97.
[13] Zhang Mingcui,Hong Wentong,Wu Xiayu,et al.A highly sensitive and direct competitive enzyme-linked immunosorbent assay for the detection of di-(2-ethylhexyl)phthalate(DEHP)in infant supplies [J].Analytical Methods,2015,13(7):5441-5446.
[14] Han Yu,Diao Donglin,Lu Zhangwei,et al.Selection of group-specific PAE-binding DNA aptamers via rational designed target immobilization and applications for ultrasensitive and highly selective detection of PAEs [J].Analytical Chemistry,2017,89(10):5270-5277.
[15] Lim H J,Kim A R,Yoon M Y,et al.Development of quantum dot aptasensor and its portable analyzer for the detection of di-2-ethylhexyl phthalate [J].Biosensors and Bioelectronics,2018,121:1-9.
[16] Tu Dandan,Garza T J,Coté L G.A SERS aptasensor for sensitive and selective detection of bis(2-ethylhexyl)phthalate [J].RSC Advances,2019,5(9):2618-2625.
[17] Yuan Zhiqi,Cai Nan,Du Yi,et al.Sensitive and selective detection of copper ions with highly stable polyethyleneimine-protected silver nanoclusters [J].Analytical Chemistry,2014,86(1):419-426.
[18] Liu Zhichao,Qi Jianwen,Hu Chun,et al.Cu nanoclusters-based ratiometric fluorescence probe for ratiometric and visualization detection of copper ions [J].Analytica Chimica Acta,2015,895:95-103.
[19] Zhang Min,Liu Yuqiang,Ye Bangce.Rapid and sensitive colorimetric visualization of phthalates using UTP-modified gold nanoparticles cross-linked by copper(II)[J].Chemical Communication,2011,47(43):11849-11851.
[20] 罗欣阳,郑悦珊,陈科.食用油塑化剂事件监测技术体系的研究 [J].广东化工,2019,46(9):79-80.
[21] 张玉环,雷亚楠,鲁皓.食品中邻苯二甲酸酯类塑化剂的检测技术研究进展 [J].食品安全质量检测学报,2021,12(1):202-209.
[22] 中华人民共和国国家标准.GB/T 39910—2020 消费品 塑胶材料 邻苯二甲酸酯类增塑剂快速筛选[S].北京:标准出版社,2020.

备注/Memo

备注/Memo:
收稿日期:2021-03-25
基金项目:国家自然科学基金面上课题(31772189)和上海市科委青年科技英才扬帆计划(18YF1421000)资助项目.
作者简介:宋 玮(1989—),女,宁夏吴忠人,副研究员,博士,主要从事农产品质量安全监测及快速检测技术研究.E-mail:songwei890214@163.com
通信作者:宋卫国(1979—),男,山东成武人,研究员,博士,主要从事农产品质量安全检测及农药毒理学研究.E-mail:sunvegous@hotmail.com